SPI0 module clock select register
SPI01_CLK_SEL | When the digital system clock selects PLL clock and the frequency of PLL clock is 480MHz, the value of reg_spi01_clk_sel: 0: SPI0/1 module clock (clk) is 80MHz. 1: SPI0/1 module clock (clk) is 120MHz. 2: SPI0/1 module clock (clk) 160MHz. 3: Not used. When the digital system clock selects PLL clock and the frequency of PLL clock is 320MHz, the value of reg_spi01_clk_sel: 0: SPI0/1 module clock (clk) is 80MHz. 1: SPI0/1 module clock (clk) is 80MHz. 2: SPI0/1 module clock (clk) 160MHz. 3: Not used. |